Volume 4, Issue 2 (11-2023)                   jste 2023, 4(2): 59-69 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

moghadas H, Tabatabai K. (2023). The Effect of H-Cap on Chimney Performance. jste. 4(2), : 6
URL: http://yujs.yu.ac.ir/jste/article-1-140-en.html
Yasouj University , h.moghadas@yu.ac.ir
Abstract:   (130 Views)
The H-type cap is one of the most widely used chimney caps in heating and industrial systems. Despite its extensive application, no specific standard has yet been established for determining the optimal dimensions of this type of cap. In the present study, the effect of the H-cap and its geometric dimensions on the performance of a chimney with a diameter of 20 cm and a height of 3 m is investigated. To generate a buoyancy-driven flow of hot air, a heat source with a constant temperature of 1800 K was placed at the bottom section of the chimney. The flow is driven solely by buoyancy forces resulting from the elevated temperature of the air surrounding the heat source, which, together with the chimney draft, induces a turbulent upward flow. This turbulent flow is modeled using the standard k-ε turbulence model. Simulations were carried out for the chimney without a cap, as well as for chimneys equipped with H-caps having various diameters and brim lengths (ranging from 15 to 25 cm). The average velocity and total pressure at the chimney inlet were evaluated for all cases. The results indicate that adding an H-cap with a diameter and brim of 20 cm reduces the average velocity by approximately 2.6%. This reduction is attributed to energy losses caused by the presence of the cap along the flow path. A cap with a diameter of 15 cm and a brim of 20 cm results in a significant reduction of 26% in velocity, whereas a cap with a diameter of 25 cm and a brim of 20 cm increases the velocity by 7%. The maximum velocity was observed for the cap with both diameter and brim equal to 25 cm, while the minimum velocity corresponded to the cap with a diameter of 15 cm and a brim of 20 cm. The findings also demonstrate that, among the various geometrical parameters, the cap diameter has a more dominant influence on chimney draft performance. Furthermore, the optimal performance is achieved when the diameter and brim of the cap are equal. These results are of considerable importance for optimal design, safety improvement, and energy efficiency enhancement.

 
Article number: 6
Full-Text [PDF 2876 kb]   (26 Downloads)    
Type of Study: Research | Subject: Special

References
1. [1] Drozdzol K. Experimental testing of an innovative steel chimney with expanded perlite insulation in the context of fire safety of buildings. Case Studies in Construction Materials. 2026; 24:e05932. [DOI: 10.1016/j.cscm. 2026.e05932] [DOI:10.1016/j.cscm.2026.e05932]
2. [2] Neri M, Drozdzol K, Bani S, Pilotelli M. Heat Transfer and Safety Risks in Horizontal Chimney Installations Through Walls. Fire Technology. 2025; 61(7):5695-718. [DOI: 10.1007/s10694-025-01804-z] [DOI:10.1007/s10694-025-01804-z]
3. [3] BRITISH. Part 1: Specification for installation of gas appliances to chimneys and for maintenance of chimneys. 2008. [DOI: behineh-sazan.ir/wp-content/uploads/2023/02/BS-5440-1-2008.pdf]
4. [4] Khavanov P, Chulenyov A. Flue Gas Removal Systems Are a Key Issue in the Application of Condensing Boilers. Journal of Physics: Conference Series. 2021; 2096(1):012057. [DOI: 10.1088/1742-6596/2096/1/012057] [DOI:10.1088/1742-6596/2096/1/012057]
5. [5] Pourhoseini SH, Mohammadpoor M, Baghban M. RSM optimization of heat recovery from the chimneys of natural gas boilers using TEGs array: An approach for simultaneous generation of electric power and preheated water. Energy Conversion and Management. 2025; 331:119691. [DOI: 10.1016/j.enconman.2025.119] [DOI:10.1016/j.enconman.2025.119691]
6. [6] Thabit Q, Nassour A, Nelles M. Flue Gas Composition and Treatment Potential of a Waste Incineration Plant. Applied Sciences. 2022; 12(10):5236. [DOI: 10.3390/app12105236] [DOI:10.3390/app12105236]
7. [7] Elehinafe FB, Aondoakaa EA, Akinyemi AF, Agboola O, Okedere OB. Separation processes for the treatment of industrial flue gases - Effective methods for global industrial air pollution control. Heliyon. 2024; 10(11). [DOI: 10.1016/j.heliyon. 2024.e32428] [DOI:10.1016/j.heliyon.2024.e32428]
8. [8] Babin T, Ramanathan S, Muthukumar S, Arun A, Subbiah S. Numerical investigation of backflow in natural draft chimneys. Materials Today: Proceedings. 2021; 45:1196-204. [DOI: 10.1016/j.matpr.2020.04.085] [DOI:10.1016/j.matpr.2020.04.085]
9. [9] Hananel A, Garcia R, Vera A. Optimization of solar chimney performance through CFD modelling and parametric experimental design. An International Journal of Optimization and Control: Theories & Applications. 2026; 16(2):428-49. [DOI: 10.36922/IJOCTA025430181] [DOI:10.36922/IJOCTA025430181]
10. [10] Zade K, Sanghai S. A comprehensive review of design parameters governing structural, aerodynamic, thermal, and environmental performance of industrial chimneys. Discover Civil Engineering. 2026; 3(1):123. [DOI: 10.1007/s44290-026-00507-w] [DOI:10.1007/s44290-026-00507-w]
11. [11] Tanriver K, Ay M. Comparison of calculation programs in a stainless-steel chimney application. Euroasia Journal of Mathematics, Engineering, Natural & Medical Sciences. 2020; 7(10):97-111. [DOI: Tanriver/publication/343232006] [DOI:10.38065/euroasiaorg.104]
12. [12] Arzpeyma, M., Mekhilef, S., Newaz, K.M.S., Horan, B., Seyedmahmoudian, M., Akram, N., Stojcevski, A., Alnaimat, F. and Mathew, B. Numerical simulation of the effect of chimney configuration on the performance of a solar chimney power plant. 2010; 2(1):1-8. [DOI: sid.ir/paper/138548/en]
13. [13] Leppänen P, Inha T, Pentti M. An experimental study on the effect of design flue gas temperature on the fire safety of chimneys. Fire Technology. 2015; 51(4):847-66. [DOI: 10.1007/s10694-014-0415-4] [DOI:10.1007/s10694-014-0415-4]
14. [14] Beygli K, Teymourtash A. Numerical simulation of the effect of a chimney as a ventilation duct by lateral injection of hot air into it. Ferdowsi University of Mashhad, Faculty of Engineering. 1396. [In Persian]. [DOI: elmnet.ir/doc/11197724-45115]
15. [15] Soofizadeh S, Pesteh SM, Amin L. Numerical study of the effect of chimney height and its distance from the rooftop parapet on chimney performance and exhaust gas dispersion in the cold season. 5th National Conference on Electrical Engineering and Mechatronics of Iran. 1398. [In Persian]. [DOI: civilica.com/doc/988442/]
16. [16] Adámek K, Jan Kolář, Pavel Peukert. Natural outlet of flue gases. AIP Conference Proceedings. 2016;1745(1):20001. [DOI: aip/acp/article-abstract/1745/1/020001/823040] [DOI:10.1063/1.4953695]
17. [17] Abbasalizadeh M, Dizji M Sh. Sliding chimney and its effect on improving efficiency and increasing chimney draft under adverse weather conditions. 4th National Symposium on Fluid Flow, Heat and Mass Transfer. 1396. [In Persian]. [DOI: civilica.com/doc/740664/]
18. [18] Antczak-Jarząbska R, Niedostatkiewicz M. Application of the Chimney Cap as a Method of Improving the Effectiveness of Natural Ventilation in Buildings. Polish Maritime Research. 2020. [DOI: 10.2478/pomr-2020-0058] [DOI:10.2478/pomr-2020-0058]
19. [19] Kalantar V, Khayyaminejad A. Numerical simulation of a combination of a new solar ventilator and geothermal heat exchanger for natural ventilation and space cooling. International Journal of Energy and Environmental Engineering. 2022; 13(2):785-804. [DOI: 10.1007/s40095-021-00463-4] [DOI:10.1007/s40095-021-00463-4]
20. [20] Samper A, Iglesias J, Herrera B, Pallares J. Flow analysis of a set of ornamental chimney caps designed by Antoni Gaudí. Heritage Science. 2020; 8(1):3. [DOI: 10.1186/s40494-019-0347-x] [DOI:10.1186/s40494-019-0347-x]
21. [21] Waite T, Murray V, Baker D. Carbon monoxide poisoning and flooding: changes in risk before, during and after flooding require appropriate public health interventions. PLoS Curr. 2014; 6. [DOI: 10.1371/currents.dis.2b2eb9e15f9b982784938803584487f1] [DOI:10.1371/currents.dis.2b2eb9e15f9b982784938803584487f1]
22. [22] Ewald B, Crisp G, Carey M. Health risks from indoor gas appliances. Australian Journal of General Practice. 2022; 51(12):935-8. [DOI:10.3316/informit.786585213635569] [DOI:10.31128/AJGP-08-22-6535]
23. [23] Semai H, Bouhdjar A. Impact of the chimney geometry on the power output of solar chimney power plant. Thermophysics and Aeromechanics. 2021; 28(2):291-303. [DOI: 10.1134/S0869864321020128] [DOI:10.1134/S0869864321020128]
24. [24] Arzpeyma M, Mekhilef S, Newaz KMS, Horan B, Seyedmahmoudian M, Akram N, Stojcevski A, Alnaimat F, Mathew B. Numerical simulation of the effect of chimney configuration on the performance of a solar chimney power plant. Journal of Thermal Analysis and Calorimetry. 2022; 147(3):2549-63. [DOI: 10.1007/s10973-021-10567-y] [DOI:10.1007/s10973-021-10567-y]
25. [25] Babaei Spouei R, Zakariapour M, Naseri R. 01 Numerical simulation of solar chimney power plant (SCPP) in southern regions of Iran using finite volume numerical simulation. Iranian Journal of Energy. 2022; 25(1):61-75. [DOI: necjournals.ir/article-1-1776]
26. [26] Felaco E, Gasser I. Modelling, asymptotic analysis and simulation of the gas dynamics in a chimney. Journal of Mathematics in Industry. 2013; 3(1):3. [DOI: 10.1186/2190-5983-3-3] [DOI:10.1186/2190-5983-3-3]
27. [27] Cui H, Chen J, Dong Z, Han Z, Liu Q. Numerical study of the fire-smoke temperature law in the shaft of a high-rise building under the chimney effect in winter. Engineering Applications of Computational Fluid Mechanics. 2023; 17(1):2222811. [DOI: 10.1080/19942060.2222811] [DOI:10.1080/19942060.2023.2222811]
28. [28] Shafiq F, Ullah A, Chughtai I, Hamid A, Nadeem M. CFD study of natural convection heat transfer from an enclosed assembly of vertical cylinders. 2017 14th International Bhurban Conference on Applied Sciences and Technology (IBCAST). 2017. [DOI: 10.1109/IBCAST.2017.7868102] [DOI:10.1109/IBCAST.2017.7868102]
29. [29] Kianifar A, Kazemi A, Sheikhan H, Pishbin SI. Modeling of heat loss from the chimney of a heater in a natural gas pressure reducing station. 1st National Conference on Environment, Energy and Biological Defense. Tehran. 2013. [In Persian]. [DOI: civilica.com/doc/264672]

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2026 CC BY-NC 4.0 | Journal of Selected Topics in Energy

Designed & Developed by : Yektaweb